Dissolved gas in ceramic ink causes most of the “mystery” faults that waste a maintenance team’s week: micro-bubbles at the nozzle plate, jetting drift that never has an obvious cause, and pump noise that comes and goes. The degassing module sits quietly in the ink circulation loop and removes that gas before it can reach the printhead, which is why a failing or badly chosen module shows up as a printing problem, not a plumbing problem.
On our store, two families of degassing modules dominate enquiries from ceramic tile plants: the 3M Liqui-Cel G638W membrane contactor used on DURST and SACMI machines, and the DIC EF-G series (EF-G5-B15 and EF-G6-B22) used on SYSTEM Ceramics lines. Buyers often ask whether they are interchangeable, which one fits their machine, and what changes if they substitute one for the other. This guide compares both families side by side and walks through a selection checklist you can apply before ordering.
Why Degassing Matters in Ceramic Ink Systems
Ceramic inks are pigment-heavy, solvent-carried dispersions that sit in a heated circulation loop for hours at a time. Dissolved air and volatile components come out of solution when pressure drops at the pump, when the ink is agitated, and when temperature swings in the loop. Once free micro-bubbles exist, three things tend to happen:
- Nozzle dropout: a bubble sitting in a nozzle channel blocks jetting intermittently, producing white lines or missing drops that move around the print.
- Pump instability: gas in the suction side of the circulation pump causes noise, flow fluctuation and, in the worst cases, cavitation damage.
- Sensor confusion: ink level, pressure and flow readings become erratic because the fluid column contains compressible gas.
A membrane contactor addresses this at the source. Ink flows past a bundle of hollow fibres while a gas gradient across the membrane wall pulls dissolved gas out of the liquid. The principle is the same for every degassing module on the market; what differs between models is the mechanical fit, the part numbering used by each OEM, and the way the module integrates with that particular machine’s ink system.
What the Site Listings Actually Cover
Before comparing the two families, it is worth being precise about what each listing is, because these modules are sold as OEM spare parts with machine-specific part numbers attached.
3M Liqui-Cel G638W (2X6, SP series)
The G638W listing is a 3M Liqui-Cel SP series membrane contactor, size reference 2X6, positioned as an original spare part for DURST and SACMI ceramic inkjet printers. It carries two OEM cross-reference numbers on the listing: 8QA801380 (the DURST-side reference) and 9620530017 (the SACMI-side reference). If your machine documentation references either of those numbers when describing the degasser, this is the module family your system was designed around.
DIC EF-G6-B22 (SYSTEM Ceramics 90018642)
The DIC EF-G6-B22 listing is an original SYSTEM Ceramics spare part, part number 90018642, built around a DIC EF-G6-B22 Liqui-Cel ink degassing module. SYSTEM Ceramics (System Ceramics, formerly System Electronic) machines reference this number in their spare parts documentation for the degassing station.
DIC EF-G5-B15 (SYSTEM Ceramics 90013844)
The EF-G5-B15 serves the same role on SYSTEM Ceramics machines that reference part number 90013844. It is the smaller sibling of the EF-G6-B22 in the DIC EF-G family, and both appear on our store in the degassing module category.
One caution applies to all three listings: none of the product pages publish flow rate, membrane area, vacuum demand or port dimensions. Wherever this article discusses performance, treat it as general membrane-contactor engineering context and confirm the exact figures against your machine manual or with us before making a purchase decision.
3M Liqui-Cel G638W vs DIC EF-G: Head-to-Head Overview
The table below summarises what each family is and where it fits. Every row is based on what the listings and OEM cross-references state publicly; anything not listed there needs confirmation against your machine documentation.
| Dimension | 3M Liqui-Cel G638W | DIC EF-G5-B15 / EF-G6-B22 |
|---|---|---|
| Module family | 3M Liqui-Cel SP series membrane contactor, 2X6 | DIC EF-G series Liqui-Cel ink module |
| OEM fit | DURST and SACMI ceramic inkjet printers | SYSTEM Ceramics printers |
| OEM cross-reference | 8QA801380 (DURST), 9620530017 (SACMI) | 90018642 (EF-G6-B22), 90013844 (EF-G5-B15) |
| Published specs | Not listed; confirm with supplier | Not listed; confirm with supplier |
| Typical failure mode | Same family: dissolved-gas breakthrough, wetting loss, seal ageing | Same family: dissolved-gas breakthrough, wetting loss, seal ageing |
Reading the table honestly: as physical devices, both families do the same job with the same working principle. The real differences that matter to a buyer are OEM fit, part-number traceability and the risk profile of substituting one for the other.
Matching the Module to the Machine
Durst and SACMI lines
If your plant runs DURST or SACMI ceramic printers, the degassing station was designed around the 3M Liqui-Cel G638W. The safest path is to order against the OEM number your parts book shows — 8QA801380 on the DURST side or 9620530017 on the SACMI side — and receive the G638W module that matches. Keeping the OEM number on your purchase record also helps when your maintenance team or an auditor traces the part back through the machine history.
SYSTEM Ceramics lines
SYSTEM Ceramics machines reference DIC EF-G modules in their parts documentation: 90018642 for the EF-G6-B22 and 90013844 for the EF-G5-B15. Which of the two your machine uses is decided by the machine model and the ink system design, not by preference — the parts book is the authority here. If your documentation shows only one of the two numbers, order against that number rather than “upgrading” to the other size on your own initiative.
When the parts book is not at hand
Plants inherit machines, and documentation gets lost. If you cannot find the OEM number, photograph the module label (both 3M and DIC modules carry identification on the housing or label) and the connection arrangement, and send it to us. Matching by label and by the machine’s make and model is far more reliable than matching by appearance, because housing sizes can look similar while flow and fitting details differ.
The Risks of Cross-Substituting Modules
The most common question we receive is whether the cheaper or faster-shipping module can stand in for the other. Our advice is to treat cross-substitution as an engineering change, not a purchase:
- Hydraulic integration: port arrangement, orientation and sealing details are designed for the host machine. Adaptation plumbing introduces joints that were never part of the original leak-review.
- Degassing balance: the machine’s ink circulation rate, vacuum arrangement and reserve volume were sized around the original module. A different module can shift the degassing balance in ways that are invisible at installation and appear weeks later as jetting drift.
- Warranty and traceability: on machines still under service contracts, a non-OEM substitution in the ink system can complicate warranty claims on downstream components.
None of this means substitution is impossible — some plants do run adapted degassing arrangements successfully under engineering supervision. But it should be a deliberate, documented decision with the machine OEM or a qualified engineer involved, not a like-for-looking-similar swap ordered from a photo.
Symptoms That Point to a Degassing Problem
Whether your line carries a G638W or an EF-G module, the failure signature is similar, because the job is the same. Watch for these patterns:
- Bubbles that return shortly after a manual purge of the ink system, then keep returning.
- Nozzle dropout concentrated in the same colour circuit while others print cleanly.
- Pump noise or flow fluctuation that correlates with ink temperature or long circulation periods.
- A rising trend in micro-bubble count if you monitor ink degassing quality, or rising vacuum demand if the machine reports it.
These symptoms overlap with suction-side air leaks and pump wear, which is why a structured diagnosis matters before you order any part. We cover the full diagnostic sequence — including how to tell degassing failure from cavitation and air ingress — in Air and Cavitation in the Ink Supply: Diagnosis and Purging. Work through that checklist first; replacing the degasser is the right call only when dissolved-gas breakthrough is confirmed as the cause.
Selection Checklist Before You Order
Before you commit to either family, run this five-point check:
1. Machine make and model. DURST/SACMI points to the 3M G638W family; SYSTEM Ceramics points to the DIC EF-G family. Anything else, ask us. 2. OEM part number from the parts book. 8QA801380 or 9620530017 for the G638W; 90018642 or 90013844 for the DIC EF-G modules. Order against the number, not the photo. 3. Physical condition of the installed module. Photograph the label, ports and mounting. Confirm the part number on the label matches the parts book. 4. Replacement versus stock decision. If you are building a spares inventory for a single machine, one module of the correct family is enough. Multi-machine plants should standardise on the OEM family per line. 5. Confirm the unknowns. Flow rating, vacuum demand, port size and service-life figures are not published on the listings. If your maintenance plan needs those numbers, request written confirmation from us or the machine OEM before you plan preventive replacement intervals.
Installation and Commissioning Notes
A degassing module replacement is a low-drama job when it is planned properly. The points that matter most:
- Wet the membrane correctly. Membrane contactors rely on the membrane staying in its intended wetting state for the ink side versus the gas side. Follow the machine’s priming procedure exactly; an incorrectly wetted membrane loses degassing performance immediately.
- Keep the gas side circuit intact. The vacuum or vent arrangement on the gas side is part of the design. Do not reroute, cap or modify it during the swap.
- Record the baseline. Before the swap, note nozzle status, pump sound and any bubble indications. After the swap, compare. A degassing module that is correctly installed shows improvement in the first hours of production, not weeks later.
- Leak check at the ports. Degassing ports are a classic slow-leak location on ceramic ink systems because the ink is carried in solvent and any seepage dries to a residue that is easy to miss in a crowded cabinet.
Maintenance and Replacement Planning
Degassing modules are wear items with long, quiet lives — they rarely fail suddenly, and the plant usually notices a gradual drift before a hard failure. Build them into your preventive replacement plan the same way you treat filters and pumps: record installation dates, trend the symptoms above, and replace on evidence rather than on a fixed guess.
For the 3M G638W specifically, we have a dedicated guide on when to replace the G638W degassing membrane, covering the operating hours, storage and symptom-based triggers in detail. Exact service-life numbers are not published on our listings; agree the interval with your ink supplier and machine OEM, and treat any published lifetime you find elsewhere as needing verification against your own duty conditions.
Frequently Asked Questions
Can I use a DIC EF-G module on a DURST or SACMI machine?
The DURST and SACMI ink systems were designed around the 3M Liqui-Cel G638W, and their parts documentation references 8QA801380 or 9620530017. Substituting a different module family is an engineering change that affects hydraulic fit and degassing balance — confirm with the machine OEM before attempting it.
Which DIC EF-G module does my SYSTEM Ceramics machine use?
Follow the parts book: 90018642 corresponds to the EF-G6-B22 and 90013844 to the EF-G5-B15. The machine model and ink system design decide which is fitted. If the documentation is unavailable, send us the label photo from the installed module.
Are the G638W and EF-G modules the same thing inside?
Both are hollow-fibre membrane contactors doing the same degassing job, but they are different OEM-specific part packages. Treat them as distinct spare parts, ordered against the OEM number your machine documentation specifies.
My new degasser is installed but bubbles keep coming back. What now?
Recurring bubbles usually mean either a suction-side air leak or an issue elsewhere in the ink loop rather than a defective new module. Work through the diagnosis and purging checklist in our cavitation and air ingress guide before replacing parts again.
Do you stock both families?
Yes — the 3M Liqui-Cel G638W and the DIC EF-G5-B15 / EF-G6-B22 modules are listed on our store with their OEM cross-reference numbers in the product titles. If you need confirmation on a specific machine pairing, contact us with the machine make and model.
Get Help Choosing the Right Degassing Module
If you are unsure which family your machine uses, or you need written confirmation of specifications for your maintenance plan, send us the machine make, model and the number from the installed module’s label. We will match it against the OEM cross-references and confirm availability before you order.
Contact LEMSUN TECH for degassing module support »
Post time: Nov-19-2026